Programming Manual 90
API_GoodRead
This function plays a sound when buzzer indication of scan module is enable and flashes the
goodread LED when the LED indication of scan module is enable.
void API_GoodRead
{
}
Parameters
None
Return Values
None.
Remarks
Use API_GoodRead() to indicate user barcode data is scanned. The buzzer indication
of scan module can be set by scan configuration program in control panel. The LED
indication of scan module can be set by SCAN_SendCommand() function. If buzzer
and LED indication are disable, the API_GoodRead will do nothing.
Example
API_GoodRead();
Requirements
OS Versions: Windows CE 5.0 and later.
Header: scanapiax.h
Link Library: scanapiax.lib
Link DLL: scanapiax.dll
Device: PA60