Argox AS-8150 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Lecteurs de codes-barres Argox AS-8150. Argox AS-8150 Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 123
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
NOTICE:
This equipment has been tested and complied with
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interface when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interface to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful interface in
which case the user will be required to correct the
interface at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2)
This device must accept any interface received,
including interface that may cause undesirable
operation.
Vue de la page 0
1 2 3 4 5 6 ... 122 123

Résumé du contenu

Page 1 - NOTICE:

NOTICE: This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits

Page 2 - Using the ArgoxScan

5Cable – K/B wedge Straight 2.0 m Cable – universal type Straight 2.3 m Connector type RJ-45 phone jack connector Case material ABS Cushion materi

Page 3 - CONTENTS

95 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < R4 > Insert

Page 4

96 RSS-Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code

Page 5

97 Exit Code ID setting 00-ffH ASCII code 00-ffH < RL > Insert group number selection 00-44 00-44 00 UCC/EAN128 emulation Disable En

Page 6 - Introduction

98 RSS-Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Trun

Page 7 - 8110 / 8120

99 Exit Min. code length 00-99 00-99 01 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII

Page 8

100Micro-PDF (for 8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Ins

Page 9

101Exit *XAI* Insert group number selection 00-44 00-44 00 *XAJ* Escape sequence transmit None GLI protocol ECI protocol 00 01 02

Page 10

102String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be tr

Page 11

103Exit Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1-22 characters 00 00-ffH ASCII code Suffix characters sett

Page 12 - Code39,PCS=45%

104String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data

Page 13

6 Programming Programming method Manual (Reading special barcode) DOS command through RS-232, Windows configuration program (8110) Program upgrade

Page 14

105Exit Option Bar Code Option Alphanumeric Entry Preamble characters setting None 1-22 characters 00 00-ffH ASCII code Preamble transmissio

Page 15 - Programming the ArgoScan

106String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with eac

Page 16 - Finish barcode

107Exit 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 6) Insert data group 1-4 position. Please refer to Chap

Page 17 - Interface Selection

108String setting / Transmission (Insert Group Characters) Insert G3 characters setting None 1-22 characters 00 00-ffH ASCII code Insert G4 c

Page 18 - Keyboard wedge

109Exit Insert data group 4 position 00-63 (00: no insertion) 00-63 00

Page 19

110String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before C

Page 20 - (83XX/8120)

111Exit Code ID position Before code data After code data 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmi

Page 21

112CODABAR-PARA (8110 *) CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-93 PARA EAN-

Page 22

113PDF-417 (8250/8312 *) STANDRAD-25 PARA CODE-16K EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA *

Page 23

114INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA RSS Micro-PDF (8312 *)

Page 24

7ArgoScan 8150 / 8250 / 8310 / 8312 Specification Model 8150/8250 Model 8310/8312 Operational Light Source 660 nm Visible Red LED 630 nm Visible R

Page 25

115ASCII Code Table

Page 26

116 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110

Page 27

117Exit Query present scanner firmware version Program Firmware version list If yo

Page 28

118 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D

Page 29 - Pin Assignments

8 Depth-head 35 mm 35 mm Weight 150 g (cable not included) 176 g (cable not included) Cable – K/B wedge Straight 2.0 m Coiled 2.5 m Cable – univ

Page 30

9Operating Temperature 0 to 45 (32 to 113 ) 0 to 45 (32 to 113 ) Storage -40 to 60 (-40 to 140 ) -20 to 60 (-4 to 140 ) Humid

Page 31

10 Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcod

Page 32

11 Option Bar Code Option Alphanumeric Entry Interface selection Keyboard Wedge RS-232 Wand emulation USB Keyboard/RS-232 Auto detection Reser

Page 33

12 Exit Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wa

Page 34

13 Exit Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a

Page 35

14 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need

Page 36

Using the ArgoxScan 8110/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code sc

Page 37

15 Exit Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04

Page 38

16 Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs c

Page 39 - Indication

17 Exit Option Bar Code Option Alphanumeric Entry Caps lock Caps lock”ON” Caps lock”OFF” 00 01 Power-on simulation Disable Enable 00 01 I

Page 40

18 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII

Page 41

19 Exit Option Bar Code Option Alphanumeric Entry Flow control None RTS/CTS Xon/Xoff ACK/NAK 00 01 02 03 Inter-character delay 00-99 (msec)

Page 42

20 Exit Option Bar Code Option Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02

Page 43 - UCC / EAN

21 Exit Wand Emulation (for 8110/8150/8250) Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low

Page 44

22 Wand Emulation (for 8110/8150/8250) Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand dec

Page 45

23 Exit Option Bar Code Option Alphanumeric Entry Output speed 620 pps 1250 pps 2500 pps 5000 pps 10000 pps 20000 pps *pps: pixel per second 0

Page 46

24 Pin Assignments AS Series 8-pin RJ-45 Connector Pin RS-232 Keyboard 1 VCC (+5V) VCC (+5V) 2 TXD NC 3 NC CLK / PC 4 NA DATA / PC

Page 47

CONTENTS Chapter 1 Introduction Introduction…………………………..………………. 1 Default Setting ………………………………………. 2 ArgoxScan8110/8120 specification ……………….. 4 Ar

Page 48

25 Keyboard Wedge Combo Connector (To Host Side): Pin Mini-DIN 6P Male DIN 5P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC

Page 49

26 Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V

Page 51

28 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when the

Page 52

29 Exit Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off Momentary Alternate Timeout off Continue Test only 00 01 02 0

Page 53

30 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code len

Page 54

31 Exit Option Bar Code Option Alphanumeric Entry Global min. code length 00-99 (00-64) 00-99 (AS-8120) 04 Global max. code length 00-99 (

Page 55

32 Scan Position indication (8110 excluded): If the function is enabled, scan beam will flash as a pointer to help you aim at the bar code prior to

Page 56

33 Exit Option Bar Code Option Alphanumeric Entry Position indication Disable 30 second 60 second 90 second 120 second 150 second 180 second

Page 57

34 Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: Af

Page 58

Telepen ………………………………………………. 80 Standard 2 of 5 ……………………………………… 82 China Post …………………………………………… 84 Italian pharmacode ………………………………… 86 Code 16K …………………

Page 59 - Code 39

35 Exit Option Bar Code Option Alphanumeric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indicatio

Page 60

36 UPCA Format Leading Zero Data Digits (11 Digits) Check Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enabl

Page 61

37 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check-sum transmission Disable Enable 00 01 Truncate leading

Page 62

38 UPCA Insertion g

Page 63 - Interleaved 2 of 5

39 Exit Option Bar Code Option Alphanumeric Entry Insert group number selection 00-44 00-44 00 Supplement digits (For 8110/8150/8250) Non

Page 64

40 UPCA Truncation

Page 65 - Industrial 2 of 5

41 Exit Option Bar Code Option Alphanumeric Entry Truncation/ Expansion (For 8110) Disable Enable 00 01 Truncation/ Expansion (For 8120/8150/

Page 66

42 UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. T

Page 67 - Matrix 2 of 5 Eur

43 Exit Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < E >

Page 68

44 UPCE Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Supplement digits: Format Leading Zero Data Di

Page 70

45 Exit Supplement digits (For 8120/8310/8312) None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 00 01 02 03 04 05

Page 71

46 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate le

Page 72 - Code-128

47 Exit Truncate ending 0-15 00-15 00 Truncation leading zero Disable Enable 00 01

Page 73

48 EAN-13 Code ID setting: Refer to page 36 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group se

Page 74

49 Exit Supplement digits (For 8110/8150/8250) None 2 digits 5 digits UCC/EAN 128 Auto detection 00 01 02 03 04 Supplement digits (For 8120/831

Page 75

50 EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leadi

Page 76 - Code-93

51 Exit Truncate ending 0-15 00-15 00 Code ID setting Two characters 00-ffH ASCII code 00-ffH, 00-ffH < FF > Insert group number selecti

Page 77

52 EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Tru

Page 78

53 Exit Truncation / Expansion (For 8110) Disable Enable 00 01 Truncation / Expansion (For 8120/8150/8250 /8310/8312) None Truncate leading zer

Page 79 - Code-11

54 Code 39 Read: Format Start “ ” Data Digits ( Variable) Checksum (Optional) End “ ” Check-sum verification: The checksum of Code-39 is optiona

Page 80

1Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable

Page 81 - MSI/plessey

55 Exit Check-sum verification Disable Enable 00 01 Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. cod

Page 82

56 Code 39 Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanc

Page 83 - UK/plessey

57 Exit Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start/end transmission Disable Enable 00 01

Page 84

58 Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of

Page 85 - Telepen

59 Exit Check-sum transmission Disable Enable 00 01 Max. code leading 00-64 00-64 00 Min. code leading 00-64 00-64 00 Truncate leading 0-

Page 86

60 Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Tr

Page 87 - Standard 2 of 5

61 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < i > Insert group numb

Page 88

62 Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of t

Page 89

63 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading

Page 90

64 Codabar Read: Format Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Tra

Page 91

2Default setting For each barcode shown as below: Code Type Read Enable Checksum Verification Enable Checksum Transmission Enable Code ID 8110

Page 92

65 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading

Page 93 - Code-16K (for 8250/8312)

66 Exit Codabar Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Start/End type: The Codabar has four p

Page 94

67 Exit Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all

Page 95 - PDF-417 (for 8250/8312)

68 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.

Page 96

69 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < # > Insert grou

Page 97 - EAN UCC Composite (for 8312)

70 Exit Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It w

Page 98

71 Exit Code-93 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is made as the

Page 99

72 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. C

Page 100

73 Exit Code ID setting 00-ffH ASCII code 00-ffH < & > Insert group number selection 00-44 00-44 00

Page 101

74 Code-11 Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The checksum is presented as the

Page 102

3 Code Type Read Enable Checksum Verification Enable Checksum Transmission Enable Code ID 8150 8250 8310 8312 UPC-A A UPC-E E EAN-13

Page 103

75 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading

Page 104

76 MSI/plessey Read: Format Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) Checksum Verification: The MSI/Plessey has one or two

Page 105 - Micro-PDF (for 8312)

77 Exit Mod 11/10 03 Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Trunc

Page 106

78 UK/plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum d

Page 107 - (Prefix / Suffix)

79 Exit Checksum Transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading

Page 108

80 Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the

Page 109 - (Preamble/Postamble)

81 Exit Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15

Page 110

82 Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check-sum verification: The checksum is made as the sum module 10 of

Page 111 - (Insert Group Characters)

83 Exit *JAC* Check-sum transmission Disable Enable 00 01 Max. code length 00-64 00-64 00 Min. code length 00-64 00-64 00 Truncate leadi

Page 112

84 China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Trunca

Page 113

4Weight 155 g 120 g ArgoScan 8110 / 8120 Specification Model 8110 Model 8120 Operational Light Source 660 nm Visible Red LED Optical System 20

Page 114

85 Exit Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH ASCII code 00-ffH < t > Ins

Page 115 - (Others)

86 Italian Pharmacode (Code 32) Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length o

Page 116

87 Exit Min. code length 00-64 00-64 09 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00 Code ID setting 00-ffH

Page 117

88 Code-16K (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.

Page 118

89 Exit Insert group number selection 00-44 00-44 00

Page 119

90 PDF-417 (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.

Page 120 - ASCII Code Table

91 Exit Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0-15 00-15 00 Truncate ending 0-15 00-15 00

Page 121

92 EAN UCC Composite (for 8312) For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the ri

Page 122

93 Exit *YAH* Code ID setting 00-ffH ASCII code 00-ffH < RC > *YAI* Insert group number selection 00-44 00-44 00 *YAK* UCC / EAN128 emu

Page 123

94 RSS-14 Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID s

Commentaires sur ces manuels

Pas de commentaire