S2K_Load
Load or unload the scan.exe.
BOOL S2K_Load
{
BOOL bLoad,
DWORD dwTimeOut
}
Parameters
bLoad
[in] To set true to load scan.exe and false to unload scan.exe
dwTimeOut
[in] When unload scan.exe it will wait until the scan.exe closed or timeout by this parameter.
Return Values
Return TRUE if the operation is successful, otherwise return FALSE.
Example
if(S2K_Load(FALSE,1000)){
AfxMessageBox(_T("unload scan.exe success"));
else
AfxMessageBox(_T("unload scan.exe failed"));
Requirements
OS Versions: Windows CE 5.0 and later.
Header: scanapiax.h
Link Library: scanapiax.lib
Link DLL: scanapiax.dll